Skip to content

moving mountain gravity wave scheme fails when ZM scheme is off #1565

@adamrher

Description

@adamrher

What happened?

The moving mountain gravity wave scheme requires the heating rate from the ZM convection scheme (it is not actually used right now, but planned to be used in the scheme in the future). When the ZM scheme is turned off (via deep_scheme='off'), the moving mountain scheme tries to grab the ZM heating pbuf, which isn't registered, and fails.

What are the steps to reproduce the bug?

Run a CAM7 compset with deep_scheme='off'.

What CAM tag were you using?

cam6_4_173

What machine were you running CAM on?

CISL machine (e.g. cheyenne)

What compiler were you using?

Intel

Path to a case directory, if applicable

No response

Will you be addressing this bug yourself?

Yes

Extra info

@JulioTBacmeister @AnonNick

Metadata

Metadata

Assignees

No one assigned

    Labels

    bugSomething isn't working correctly

    Type

    No type
    No fields configured for issues without a type.

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions